Commercial Slush Machine Troubleshooting: Common Problems and Fixes
Commercial slush machines are workhorses during peak seasons, but problems can arise. Here's a quick troubleshooting guide.
Problem: Machine not freezing
Check: Power supply? Freezing switch on? Refrigerant level? Condenser coils clean? Most common cause: dirty condenser coils - clean monthly.
Problem: Slush too thin/watery
Check: Brix level of mix (recommended 12-14°Bx)? Freezing time sufficient? Agitator mechanism working?
Problem: Machine making loud noise
Check: Agitator bearing worn? Mix level too low? Machine on uneven surface?
Problem: Slush too thick
Check: Brix level too high? Freezing temperature set too low?
For persistent issues, contact Finos technical support for remote diagnosis.